进口塑胶料
注:请在右边的搜索栏查找产品

PA66 EFE6096 GY090A 含15%矿物增强

添加时间:2013-11-16  信息来源:http://www.xzslw.com/  作者:苏州希普能塑料

Minlon PA66 EFE6096 GY090A

Minlon® EFE6096 GY090A | PA66-I-MD15 MINERAL REINFORCED NYLON RESIN
 
Regional Availability
Europe, Near East/Africa
 
Processing
Injection Moulding
 
Delivery form
Pellets
 
Additives
Release agent
 
Special characteristics
Heat stabilised or stable to heat
 
Product Text
Common features of Minlon® nylon resin include mechanical and physical properties such as high mechanical strength, excellent balance of stiffness /toughness, good high temperature performance, good chemical resistance, paintability, dimensional stability and low warpage.
 
Grades with improved electrical and flammability properties are available within the Zytel® nylon resin product line. In addition, Minlon® nylon resin is available in different modified and reinforced grades to create a wide range of products with tailored properties for specific processes and end-uses.
 
The good melt stability of Minlon® nylon resin normally enables the recycling of properly handled production waste. If recycling is not possible, DuPont recommends, as the preferred option, incineration with energy recovery (-31kJ/g of base polymer) in appropriately equipped installations. For disposal, local regulations have to be observed.
 
Minlon® nylon resin typically is used in demanding applications in the automotive, electrical, electronic, domestic appliances and construction industries.
 
Minlon® EFE6096 GY090A is a 15% mineral reinforced impact modified nylon 66 resin.
 
Injection molding
PREPROCESSING
Drying recommended = Yes, if moisture content of resin exceeds recommended level
Drying temperature = 80℃
Drying time, dehumidified dryer = 2-4 h
Processing moisture content = <0.2 %
 
PROCESSING
Melt temperature optimum = 295℃
Melt temperature range = 285-305℃
Mould temperature optimum = 100℃
Mould temperature range = 70-120℃
Maximum Screw tangential Speed : 0.15 m/s
Flow front speed : 100 mm/s
Hold pressure optimum : 70 MPa
Hold pressure range : 40-100 MPa
Back pressure : low
Hold pressure time : 3 s/mm
Maximum hold-up time : 8 min
 
PROPERTIES
Rheological properties dry / cond Unit Test Standard
Moulding shrinkage,parallel 1.1 / * % ISO 294-4,2577
Moulding shrinkage,normal 1.1 / * % ISO 294-4,2577
Mechanical properties dry / cond Unit Test Standard
Tensile Modulus 3800 / 1800 MPa ISO 527-1/-2
Stress at 50% strain * / 50 MPa ISO 527-1/-2
Stress at break 76 / 52 MPa ISO 527-1/-2
Strain at break 21 / >50 % ISO 527-1/-2
Charpy impact strength,23℃ 100 / N kJ/m² ISO 179/1eU
Charpy impact strength,-30℃ 6 / - kJ/m² ISO 179/1eU
Charpy notched impact strength,23℃ 7.5 / 15 kJ/m² ISO 179/1eA
Charpy notched impact strength,-30℃ 6 / 4 kJ/m² ISO 179/1eA
Thermal properties dry / cond Unit Test Standard
Melting temperature,10℃/min 263 / * ISO 11357-1/-3
Temp. of deflection under load,1.8 MPa 75 / * ISO 75-1/-2
Temp. of deflection under load,0.45 MPa 212 / * ISO 75-1/-2
Vicat softening temperature,50℃/h,50N 235 / * ISO 306
Coeff. of linear therm. expansion,parallel 100 / * E-6/K ISO 11359-1/-2
Coeff. of linear therm. expansion,normal 100 / * E-6/K ISO 11359-1/-2
Electrical properties dry / cond Unit Test Standard
Dissipation factor,100Hz 230 / 2100 E-4 IEC 60250
Dissipation factor,1MHz 230 / 550 E-4 IEC 60250
Volume resistivity - / 1E10 Ohm*m IEC 60093
Electric strength 40 / - kV/mm IEC 60243-1
Comparative tracking index 575 / - - IEC 60112
Other properties dry / cond Unit Test Standard
Water absorption,2mm 7.7 / * % Sim. to ISO 62
Humidity absorption,2mm 2.1 / * % Sim. to ISO 62
Density 1230 / - kg/m³ ISO 1183
Material specific properties dry / cond Unit Test Standard
Viscosity number 150 / * cm³/g ISO 307,1157,1628
Rheological calc. properties Value Unit Test Standard
Density of melt 1080 kg/m³ -
Thermal conductivity of melt 0.19 W/(m K) -
Spec. heat capacity melt 2320 J/(kg K) -
Ejection temperature 190 -
Min. mould temperature 70 -
Max. mould temperature 120 -
Min. melt temperature 285 -
Max. melt temperature 305 -
VDA Properties Value Unit Test Standard
Emission of organic compounds 6.5 µgC/g VDA 277
Odour 3.5 class VDA 270

 

Chemical Media Resistance
Acids
√ Acetic Acid (5% by mass) (23℃)
√ Citric Acid solution (10% by mass) (23℃)
√ Lactic Acid (10% by mass) (23℃)
× Hydrochloric Acid (36% by mass) (23℃)
× Nitric Acid (40% by mass) (23℃)
× Sulfuric Acid (38% by mass) (23℃)
× Sulfuric Acid (5% by mass) (23℃)
× Chromic Acid solution (40% by mass) (23℃)
Bases
× Sodium Hydroxide solution (35% by mass) (23℃)
√ Sodium Hydroxide solution (1% by mass) (23℃)
√ Ammonium Hydroxide solution (10% by mass) (23℃)
Alcohols
√ Isopropyl alcohol (23℃)
√ Methanol (23℃)
√ Ethanol (23℃)
Hydrocarbons
√ n-Hexane (23℃)
√ Toluene (23℃)
√ iso-Octane (23℃)
Ketones
√ Acetone (23℃)
Ethers
√ Diethyl ether (23℃)
Mineral oils
√ SAE 10W40 multigrade motor oil (23℃)
√ SAE 10W40 multigrade motor oil (130℃)
√ SAE 80/90 hypoid-gear oil (130℃)
√ Insulating Oil (23℃)
Standard Fuels
√ ISO 1817 Liquid 1 (60℃)
√ ISO 1817 Liquid 2 (60℃)
√ ISO 1817 Liquid 3 (60℃)
√ ISO 1817 Liquid 4 (60℃)
√ Standard fuel without alcohol (pref. ISO 1817 Liquid C) (23℃)
√ Standard fuel with alcohol (pref. ISO 1817 Liquid 4) (23℃)
√ Diesel fuel (pref. ISO 1817 Liquid F) (23℃)
√ Diesel fuel (pref. ISO 1817 Liquid F) (90℃)
√ Diesel fuel (pref. ISO 1817 Liquid F) (>90℃)
Salt solutions
√ Sodium Chloride solution (10% by mass) (23℃)
× Sodium Hypochlorite solution (10% by mass) (23℃)
√ Sodium Carbonate solution (20% by mass) (23℃)
√ Sodium Carbonate solution (2% by mass) (23℃)
× Zinc Chloride solution (50% by mass) (23℃)
Other
√ Ethyl Acetate (23℃)
× Hydrogen peroxide (23℃)
√ DOT No. 4 Brake fluid (130℃)
√ Ethylene Glycol (50% by mass) in water (108℃)
√ 1% nonylphenoxy-polyethyleneoxy ethanol in water (23℃)
√ 50% Oleic acid + 50% Olive Oil (23℃)
√ Water (23℃)
× Water (90℃)
× Phenol solution (5% by mass) (23℃)

 

Symbols used:
√ possibly resistant
Defined as: Supplier has sufficient indication that contact with chemical can be potentially accepted under the intended use conditions and expected service life. Criteria for assessment have to be indicated (e.g. surface aspect, volume change, property change).

 

× not recommended - see explanation
Defined as: Not recommended for general use. However, short-term exposure under certain restricted conditions could be acceptable (e.g. fast cleaning with thorough rinsing, spills, wiping, vapor exposure).

希普能工程塑料