进口塑胶料
注:请在右边的搜索栏查找产品

PA66 70G30HSL BK039B 含30%玻璃纤维增强,热稳定

添加时间:2013-11-19  信息来源:http://www.xzslw.com/  作者:苏州希普能塑料

DuPont PA66 70G30HSL BK039B

Zytel® 70G30HSL BK039B | PA66-GF30 NYLON RESIN
 
Regional Availability
Europe, Near East/Africa
 
Processing
Injection Moulding
 
Delivery form
Pellets
 
Additives
Lubricants, Release agent
 
Special characteristics
Heat stabilised or stable to heat
 
Product Text
ASTM D6779 PA012G30 A53480
 
Common features of Zytel® nylon resin include mechanical and physical properties such as high mechanical strength, excellent balance of stiffness and toughness, good high temperature performance, good electrical and flammability properties, good abrasion and chemical resistance. In addition, Zytel® nylon resins are available in different modified and reinforced grades to create a wide range of products with tailored properties for specific processes and end-uses. Zytel® nylon resin, including most flame retardant grades, offer the ability to be coloured.
 
The good melt stability of Zytel® nylon resin normally enables the recycling of properly handled production waste. If recycling is not possible, DuPont recommends, as the preferred option, incineration with energy recovery (-31kJ/g of base polymer) in appropriately equipped installations. For disposal, local regulations have to be observed.
 
Zytel® nylon resin typically is used in demanding applications in the automotive, furniture, domestic appliances, sporting goods and construction industry.
 
Zytel® 70G30HSL BK039B is a 30% glass reinforced, heat stabilized, black nylon 66 resin for injection molding.
 
Injection molding
PREPROCESSING
Drying recommended = Yes, if moisture content of resin exceeds recommended level
Drying temperature = 80℃
Drying time, dehumidified dryer = 2-4 h
Processing moisture content = <0.2 %
 
PROCESSING
Melt temperature optimum = 295℃
Melt temperature range = 285-305℃
Mould temperature optimum = 100℃
Mould temperature range = 70-120℃
Maximum Screw tangential Speed : 0.15 m/s
Flow front speed : 150 mm/s
Hold pressure optimum : 85 MPa
Hold pressure range : 50-100 MPa
Back pressure : low
Hold pressure time : 2.5 s/mm
Maximum hold-up time : 15 min
 
PROPERTIES
Rheological properties dry / cond Unit Test Standard
Moulding shrinkage,parallel 0.3 / * % ISO 294-4,2577
Moulding shrinkage,normal 1.1 / * % ISO 294-4,2577
Mechanical properties dry / cond Unit Test Standard
Tensile Modulus 9900 / 7000 MPa ISO 527-1/-2
Stress at break 187 / 124 MPa ISO 527-1/-2
Strain at break 3 / 4.5 % ISO 527-1/-2
Tensile creep modulus,1h * / 6800 MPa ISO 899-1
Tensile creep modulus,1000h * / 5100 MPa ISO 899-1
Charpy impact strength,23℃ 75 / 80 kJ/m² ISO 179/1eU
Charpy impact strength,-30℃ 70 / 70 kJ/m² ISO 179/1eU
Charpy notched impact strength,23℃ 10 / 12 kJ/m² ISO 179/1eA
Charpy notched impact strength,-30℃ 9 / 9 kJ/m² ISO 179/1eA
Puncture - maximum force,23℃ 970 / - N ISO 6603-2
Puncture energy,23℃ 4.5 / - J ISO 6603-2
Thermal properties dry / cond Unit Test Standard
Melting temperature,10℃/min 263 / * ISO 11357-1/-3
Glass transition temperature,10℃/min 80 / - ISO 11357-1/-2
Temp. of deflection under load,1.8 MPa 250 / * ISO 75-1/-2
Temp. of deflection under load,0.45 MPa 258 / * ISO 75-1/-2
Vicat softening temperature,50℃/h,50N 250 / * ISO 306
Flammability dry / cond Unit Test Standard
Burning Behav. at 1.5 mm nom. thickn. HB / * class IEC 60695-11-10
Thickness tested 1.5 / * mm IEC 60695-11-10
UL recognition UL / * - -
Burning Behav. at thickness h HB / * class IEC 60695-11-10
Thickness tested 0.8 / * mm IEC 60695-11-10
Oxygen index 24 / * % ISO 4589-1/-2
Glow Wire Flammability Index,1mm 700 / - IEC 60695-2-1/2
Glow Wire Flammability Index,2mm 750 / - IEC 60695-2-1/2
Glow Wire Flammability Index,3mm 800 / - IEC 60695-2-1/2
Glow Wire Ignition Temperature,1mm 725 / - IEC 60695-2-1/3
Glow Wire Ignition Temperature,2mm 725 / - IEC 60695-2-1/3
Glow Wire Ignition Temperature,3mm 775 / - IEC 60695-2-1/3
Glow Wire Temperature,No Flame,1mm 700 / - IEC 60335-1
Glow Wire Temperature,No Flame,2mm 700 / - IEC 60335-1
Glow Wire Temperature,No Flame,3mm 750 / - IEC 60335-1
Electrical properties dry / cond Unit Test Standard
Relative permittivity,100Hz 4.4 / 11 - IEC 60250
Relative permittivity,1MHz 4.1 / 4.6 - IEC 60250
Dissipation factor,100Hz 70 / 4600 E-4 IEC 60250
Dissipation factor,1MHz 150 / 650 E-4 IEC 60250
Volume resistivity >1E13 / 1E9 Ohm*m IEC 60093
Surface resistivity * / 1E13 Ohm IEC 60093
Electric strength 38 / 32 kV/mm IEC 60243-1
Comparative tracking index 400 / - - IEC 60112
Other properties dry / cond Unit Test Standard
Water absorption,2mm 6 / * % Sim. to ISO 62
Humidity absorption,2mm 1.9 / * % Sim. to ISO 62
Density 1370 / - kg/m³ ISO 1183
Material specific properties dry / cond Unit Test Standard
Viscosity number 150 / * cm³/g ISO 307,1157,1628
Rheological calc. properties Value Unit Test Standard
Density of melt 1200 kg/m³ -
Thermal conductivity of melt 0.21 W/(m K) -
Spec. heat capacity melt 2290 J/(kg K) -
Eff. thermal diffusivity 6.85E-08 m²/s -
Ejection temperature 190 -
Min. mould temperature 65 -
Max. mould temperature 120 -
Min. melt temperature 280 -
Max. melt temperature 305 -
VDA Properties Value Unit Test Standard
Burning rate,Thickness 1 mm 20 mm/min ISO 3795 (FMVSS 302)
Emission of organic compounds 10 µgC/g VDA 277
Odour 3 class VDA 270

 

Chemical Media Resistance

Acids

√ Acetic Acid (5% by mass) (23℃)

√ Citric Acid solution (10% by mass) (23℃)

√ Lactic Acid (10% by mass) (23℃)

× Hydrochloric Acid (36% by mass) (23℃)

× Nitric Acid (40% by mass) (23℃)

× Sulfuric Acid (38% by mass) (23℃)

× Sulfuric Acid (5% by mass) (23℃)

× Chromic Acid solution (40% by mass) (23℃)

Bases

× Sodium Hydroxide solution (35% by mass) (23℃)

√ Sodium Hydroxide solution (1% by mass) (23℃)

√ Ammonium Hydroxide solution (10% by mass) (23℃)

Alcohols

√ Isopropyl alcohol (23℃)

√ Methanol (23℃)

√ Ethanol (23℃)

Hydrocarbons

√ n-Hexane (23℃)

√ Toluene (23℃)

√ iso-Octane (23℃)

Ketones

√ Acetone (23℃)

Ethers

√ Diethyl ether (23℃)

Mineral oils

√ SAE 10W40 multigrade motor oil (23℃)

√ SAE 10W40 multigrade motor oil (130℃)

√ SAE 80/90 hypoid-gear oil (130℃)

√ Insulating Oil (23℃)

Standard Fuels

√ ISO 1817 Liquid 1 (60℃)

√ ISO 1817 Liquid 2 (60℃)

√ ISO 1817 Liquid 3 (60℃)

√ ISO 1817 Liquid 4 (60℃)

√ Standard fuel without alcohol (pref. ISO 1817 Liquid C) (23℃)

√ Standard fuel with alcohol (pref. ISO 1817 Liquid 4) (23℃)

√ Diesel fuel (pref. ISO 1817 Liquid F) (23℃)

× Diesel fuel (pref. ISO 1817 Liquid F) (90℃)

× Diesel fuel (pref. ISO 1817 Liquid F) (>90℃)

Salt solutions

√ Sodium Chloride solution (10% by mass) (23℃)

× Sodium Hypochlorite solution (10% by mass) (23℃)

√ Sodium Carbonate solution (20% by mass) (23℃)

√ Sodium Carbonate solution (2% by mass) (23℃)

× Zinc Chloride solution (50% by mass) (23℃)

Other

√ Ethyl Acetate (23℃)

× Hydrogen peroxide (23℃)

√ DOT No. 4 Brake fluid (130℃)

√ Ethylene Glycol (50% by mass) in water (108℃)

× Coolant Glysantin G48, 1:1 in water (130℃)

√ 1% nonylphenoxy-polyethyleneoxy ethanol in water (23℃)

√ 50% Oleic acid + 50% Olive Oil (23℃)

√ Water (23℃)

√ Water (90℃)

× Phenol solution (5% by mass) (23℃)

 

Symbols used:

√ possibly resistant

Defined as: Supplier has sufficient indication that contact with chemical can be potentially accepted under the intended use conditions and expected service life. Criteria for assessment have to be indicated (e.g. surface aspect, volume change, property change).

 

× not recommended - see explanation

Defined as: Not recommended for general use. However, short-term exposure under certain restricted conditions could be acceptable (e.g. fast cleaning with thorough rinsing, spills, wiping, vapor exposure).

希普能工程塑料